Wood Acoustic Panelling for Walls: Specification Checklist
Home > Acoustic Wood Panels




Wood acoustic Panelling For Walls
Category
Wooden Slat Panel
A useful wood acoustic wall specification describes the product and the work needed to install it. A finish name alone leaves important decisions about the core, backing, edges and supports unresolved.
Describe the wall lining
List the panel model, dimensions, thickness, slat spacing, face finish and backing. State whether quoted dimensions are nominal or finished. Mark any required exposed edges and returns; a front-facing sample may not represent how a cut panel will look at a corner.
Define installation responsibilities
Identify the substrate and required preparation. Ask for the fixing detail approved for that product and surface. Allocate measurement, cutting, service coordination and waste removal to named parties. Confirm who reviews changes if a socket, door frame or uneven wall interrupts the layout.
Request documents by purpose
Separate acoustic absorption evidence from fire, emissions and material sourcing documents. Match each report to the actual construction and application rather than accepting a general brochure statement. A specification should not invent a rating that has not been established for the supplied system.
Approve a coordinated sample
Keep the finish sample, wall elevation and written specification together. Use the wood slat acoustic panel range for model discussions, the shop drawing checklist for drawing content and the sample approval checklist for the approval record. Record any accepted variations before the order is released.
Copyable wood acoustic wall specification record
Complete the fields with the selected product information; blank fields are questions for the supplier or project team, not permission to infer a rating.
| Specification field | Information to record | Supporting reference |
|---|---|---|
| Product and dimensions | Model, finished width, length, total thickness and tolerances | Current product schedule |
| Face and core | Face finish, slat/core material, spacing and visible edges | Accepted sample and section |
| Backing and mounting | Backing, cavity, supports and attachment | Installation detail and substrate record |
| Acoustic evidence | Report, specimen and mounting corresponding to the proposal | Report number and relevant assembly |
| Other project evidence | Required fire, emissions and sourcing documents, with availability stated | Exact product and document scope |
| Quantities and responsibilities | Full panels, cuts, trims, spares, measurement and installation parties | Elevation, cutting schedule and quotation |
| Care and handover | Approved cleaning, access and replacement reference | Product care instructions and handover record |
Coordinate the record with the slat joint and edge plan and installation guide. For US delivery, add the destination ZIP code and site constraints; confirm packing, freight and delivery responsibilities separately.
Write a Clear Specification for Wood Acoustic Panelling
Wood acoustic panelling for walls combines a decorative surface with an acoustic function that depends on the complete assembly. A useful project specification identifies the panel construction, finish, dimensions, mounting and applicable evidence, rather than relying only on a colour name or a general product photograph.
This checklist is intended for designers, contractors and procurement teams preparing an interior wall package. Review the wood slat acoustic panel range alongside your drawings and samples.
Identify the Construction

State the slat core, surface finish and backing as separate items. A wood veneer surface does not mean the entire slat is solid wood, and a wood-look finish should not be described as natural veneer without confirmation. Match the approved sample to a product code that can be used on drawings, quotations and delivery labels.
Read the veneer, core and backing guide when comparing material descriptions. Confirm which construction is being offered for your order.
Record Dimensions and the Finished Build-up
Specify panel width and length, slat width and spacing, overall panel thickness and the proposed mounting arrangement. Where battens or a cavity are required, show the total projection from the existing wall, not just the panel thickness.
Check the actual wall height before selecting a full-height panel. Available lengths, site tolerances, skirting and ceiling details determine whether a joint is needed. Do not assume one nominal panel length will fit every room without cutting or a planned joint.



For the previously listed model references, see the SN35-15 and LD27-13 specification guide. Confirm current dimensions and available combinations with the quotation.
Approve Finish and Edge Appearance



Use physical samples under the intended lighting. Record the finish code, backing colour and acceptable variation. If natural veneer is selected, review grain variation across several pieces rather than expecting every slat to look identical.
Show exposed ends, corners and interfaces with adjoining materials on the drawings. Confirm whether cut edges need finishing and who provides the trim or treatment. The panel layout, joints and edges guide helps coordinate these details.
Match Performance Evidence to the Assembly
Request the acoustic report for the proposed product and mounting configuration. Check the backing, cavity, insulation and test method before using a result in a schedule. Sound absorption data do not establish a partition sound-isolation rating.
Fire documentation should identify the relevant product or assembly and its conditions of use. A classification for backing material alone should not be described as the classification of every finished panel. Apply the same scope check to emissions and material sourcing documents.
Our performance evidence checklist provides questions to ask before approving product claims.
Coordinate Fixings and Building Services
Identify the substrate and confirm a suitable fixing method. Show sockets, access panels, switches and equipment on the wall elevation. Shelves and screens need their own appropriate support; decorative slats should not be treated as structural fixings.
Include installation responsibilities in the specification: substrate preparation, cutting, edge finishing, waste removal and final inspection. Ceiling applications require a separately confirmed overhead system.
Use a Submittal Checklist
| Document | Approval point |
|---|---|
| Product drawing | Construction, dimensions, weight and mounting arrangement. |
| Finish sample | Surface, backing colour, variation and edge appearance. |
| Wall elevation | Orientation, joints, corners and services. |
| Performance documents | Applicable product, assembly and project requirements. |
| Order schedule | Quantities, spare allowance, packing and delivery basis. |
| Handover record | Care guidance, product identification and replacement information. |
Questions Before Final Approval
Can one specification cover all wood slat finishes?
Not automatically. Changes in core, finish, backing or installation may affect the relevant evidence and care requirements. Identify the approved combination.
Can the sample approval replace technical documents?
No. Samples establish visual and tactile expectations; technical documents address construction and performance. Both are useful for a clear project record.
Send your wall drawings, finish requirements and documentation needs for a quotation aligned with the specification.